Subsystem
Transducers:
LF 1× 12-in cone
HF 1×1-in exit, 1.75 in voice coil compression driver
Loading
LF: Vented
HF: Horn-loaded
Operating Mode
Bi-amp LF, HF
Signal Processing
DSP w/EAW Focusing™ and DynO™
ACCOUSTICAL PERFORMANCE
Operating Range
55 Hz to 19 kHz
Nominal Beamwidth (rotatable)
Horizontal 90°
Vertical 60°
Axial Output Limit Peak
LF/HF 135 dB
Axial Output Limit Long Term
LF/HF 129 dB
ELECTRICAL PERFORMANCE
Input
Electronically balanced XLRF
Loop
Electronicallly balanced XLRM
Amplifier
LF
Class D
1000 W @ 8 ohm
Integral DSP limiting
HF
Class D
250 W @ 8 ohm
Integral DSP limiting
AC Mains (nominal)
Neutrik PowerCon
50 Hz to 60 Hz
100V to 240V
Indicators (LED)
Amplifier Status
Signal Present
Limiter Active
Clip
Voicing Mode 3x